Solahart Atmos® Eco: Key Attributes
Key Features
WHY ATMOS ECO IS A SMART CHOICE
A Solahart Atmos® Eco 180 Heat Pump is the smart choice for people who are looking for an energy-efficient alternative to a small to medium-sized electric water heater but are unable to install a solar water heater. It heats water by drawing heat from the surrounding air, is a reliable and efficient way to reduce energy consumption and cut greenhouse gas emissions, and is a sustainable way to reduce your water heating energy consumption without the need for rooftop solar collectors.
- High COP OF 4.9: Coefficient of Performance (COP) of 4.9 @ 19oC ambient air temperature.1
- Can save up to 70% on your water heating energy use: when compared to an electric water heater in Zone 3.2
- Suitable for cold climates: With an operating range from -7°C to +43°C. It is also suitable for harsh water conditions.
- Microchannel Technology: Provides a larger contact area to maximise heat transfer efficiency. The advanced wraparound design provides uniform and faster water heating.
- User-Friendly LED Controller Display: For easy operation.
- Government Incentives: Eligible for STCs (may be eligible for additional incentives in some states).
*Warranty Details
- 7 years cylinder supply
- 3 years cylinder labour
- 3 years sealed system supply and labour
- 1 year parts supply and labour
*The warranty periods above apply to installations in a single-family domestic dwelling only. For further details, please refer to the Owner’s Guide. Without limiting the above periods, a 5-year whole-of-product warranty applies where a rebate has been received under Solar Victoria’s Solar Homes Program for the installation of a Solahart Atmos Eco 180HDC Heat Pump. See the Solahart warranty set out in the Owner’s Guide and Installation Instructions. For more details call Solahart Australia 1300 769 475.
1 See datasheet for detailed specifications.
2 Energy savings of up to 70% in Zone 3 based on TRNSYS modelling on hot water energy consumption when replacing an electric water heater of a similar size with a Solahart Atmos® Eco 180HDC Heat Pump. Any savings will vary depending upon your location, type of water heater being replaced, hot water consumption and fuel tariff.
Solahart Atmos® Eco 180 Technical Specifications
Technical | |
---|---|
Storage Capacity (Litres) | 178 |
Boost Capacity (litres) | 168 |
Dimensions H x W x D (mm) | 1810 x 532 x 576 |
Weight - Empty (cartoned) (kg) | 116 |
Weight - Full (kg) | 284 |
Temperature Setting (°C) | 60 |
Maximum Rated Power Input @ 240 V (Watts) | 3500 |
Rated Heat Pump Power Input (Watts) | 683 |
Refrigerant | R513A |
Element Size (kW) | 2.4 |
Noise Rating @ 1 m [dB(A)] | 48 |
IP Rating | IP24 |
Average COP @ 19°C ambient air temperature & from 10°C to 60°C water temperature * | 4.9 |
Average Heat Pump Heating Capacity @ 19°C Ambient air temperature & from 10°C to 60°C water temperature * (kW) | 3.2 |
Water Connections & Settings | |
Water Inlet/Outlet Connections | Rp 3/4 |
Temperature Pressure Relief Valve Setting (kPa) | 1000 |
ECV Setting (kPa) (not supplied) | 850 |
Maximum Mains Supply Pressure | |
With ECV (kPa) | 680 |
Without ECV (kPa) | 800 |
* An average Coefficient of Performance (COP) value of 4.9 was measured under test conditions with an ambient air temperature of 19˚C/15˚C (Dry Bulb/Wet Bulb) over the entire heat-up process, heating of the water from 10˚C to 60˚C during water heater operation and a power supply of 240 V~ 50 Hz. The Heat Pump average heating capacity in Watts and its water heating capacity in Litres / hour were calculated from the results of this test. The heat pump water heater performance tests were conducted to AS/NZS 5125.1:2014. Note that the actual COP of the product at any given time will be impacted by a number of factors, including the ambient air and cold-water inlet temperatures at the place of installation and time of day/season of operation.
The Coefficient of Performance (COP) for a heat pump is the ratio of how much useful heat it produces for water heating to the power input into the water heater. The higher the COP number, the more efficient the heat pump is.