Atmos-Frost: Key Attributes

Key Features

WHY ATMOS FROST IS A SMART CHOICE

Solahart Atmos-Frost is an energy efficient Heat Pump Water Heater designed to be installed in areas where traditional solar hot water systems may not be suitable. The Solahart Atmos-Frost Heat Pump can be installed in almost any location in Australia, as it is suitable for harsh water, cold climates, and tropical conditions.

  •  COP OF 4.5: Coefficient of Performance (COP) of 4.5** making it a highly efficient water heater to help reduce energy consumption
  •  Enamel-Lined Water Tank The high-quality durable enamel coating reduces the risk of corrosion and water leakage.
  •  Side Fan Design: A design that provides maximum airflow and protects from the rain.
  •  Micro-channel Technology: Provides a larger contact area to maximise heat transfer efficiency. The wrap-around design of the micro-channels enables installation in harsh water areas.
  •  Smart LED Controller Display: A bright interactive LED touchscreen display putting control at your fingertips
  •  Heavy Duty Top Cover: The ASA^ top cover withstands harsh weather conditions.

* Solahart Warranty Details: 7/3/2 warranty; 7-year cylinder supply, 3-year labour on cylinder, 2-year parts including labour. Applies to a single-family domestic dwelling only. Without limiting these periods, a 5-year whole-of-product warranty applies where a rebate has been received under Solar Victoria’s Solar Homes Program for installations from 1st July 2023. See the Solahart warranty set out in the Owner’s Guide and Installation Instructions. For more details call Solahart Australia 1300 769 475.

 


All other applications have a 3/1/1 warranty; 3-year cylinder supply, 1-year cylinder labour, 1-year parts, including labour. 

** Testing condition: 19°C/15°C (Dry bulb/Wet bulb), relative humidity of 66% and heating water from 15°C to 60°C.

^ Acrylonitrile Styrene Acrylate (ASA) is an amorphous thermoplastic with improved weather resistance.

Atmos Frost 270 Technical Specifications

 

Technical
Storage Capacity (Litres) 270
Boost Capacity (litres) 195
Dimensions H x W x D (mm) 1825 x 725 x 690
Weight - Empty (cartoned)  (kg) 145
Weight - Full (kg) 405
Temperature Setting (°C) 60
Maximum Rated Power Input @ 240 V (Watts) 3600
Rated Heat Pump Power Input (Watts) 985
Refrigerant R134a
Element Size (kW) 2.4
Noise Rating @ 1 m [dB(A)] 47
IP Rating IP24
Coefficient of Performance 4.5*
Water Connections & Settings
Water Inlet/Outlet Connections Rp 3/4
Temperature Pressure Relief Valve Setting (kPa) 1000
ECV Setting (kPa) (not supplied) 850
Maximum Mains Supply Pressure
With ECV (kPa) 680
Without ECV (kPa) 800

* Testing condition: 19°C/15°C (Dry bulb/Wet bulb), 66% relative humidity and heating water from 15°C to 60°C.

How Heat Pump Water Heaters Work

The efficient heat pump technology extracts energy from the surrounding air. Ambient warmth is used to convert the refrigerant within the sealed system into a gas. The gas is then compressed to generate even more heat which then heats the water in the tank. What’s more this process can work day or night, in sunshine and rain, all year round.

When hot water is drawn off and cold water enters the tank, the thermostat activates the fan and the compressor. The operation of the compressor causes a pressure difference within the sealed refrigeration system. This pressure difference causes the refrigerant to move around the sealed system. The refrigerant enters the evaporator as a liquid. As the refrigerant absorbs heat from the atmosphere it changes state, at low pressure, from a sub cooled liquid to a super-heated vapour or gas (evaporates). The vapour then enters the compressor and obtains more heat, known as heat of compression, and passes into the heat exchanger as a super-heated vapour at high pressure.

As the refrigerant passes through the micro-channel heat exchanger wrapped around the storage cylinder, it gives off heat which is absorbed by the water inside the cylinder. As the refrigerant gives off heat it cools and changes state back into a liquid (condenses). The refrigerant then enters the evaporator again and the cycle is repeated. The resulting cold air is then discharged through the air outlet louvers back to atmosphere. This process continues while ever heating is required until the water in the storage tank reaches a temperature of 60°C.  

User-Friendly Smart Control

The Solahart Atmos-Air Heat Pump comes with an inbuilt touch LCD display. It is user-friendly and boasts a range of features, operation modes and settings:

  • Clock
  • Usable hot water quantity display
  • Water temperature display
  • Dual timer function
  • Vacation Mode - conserve energy when you are on holidays
  • Manual electric heating mode - For emergency hot water requirements in the event of the heat pump developing a fault 
  • Automatic de-icing Function - automatic de-icing in frost conditions

The Smart Way To Create Hot Water Out Of Thin Air

ATMOS Frost Brochure Data Sheet: Download

ATMOS Frost Brochure Flyer: Download

ATMOS Frost Owner's Guide and Installation Instructions: Download